Equipment / Ulthera System
Image/Treat Transducer with Linear Treatment Guides
No reviews yetKey attributes
- Image depth
- up to 8 millimeters
- Scan length
- 25 mm
- Transducer type DS 7-3.0 treat frequency
- 7 MHz
- Transducer type DS 7-3.0 treat depth
- 3.0 mm
- Transducer type DS 4-4.5 treat frequency
- 4 MHz
- Transducer type DS 4-4.5 treat depth
- 4.5 mm
Similar products
Key attributes
| Image depth | up to 8 millimeters |
|---|---|
| Scan length | 25 mm |
| Transducer type DS 7-3.0 treat frequency | 7 MHz |
| Transducer type DS 7-3.0 treat depth | 3.0 mm |
| Transducer type DS 4-4.5 treat frequency | 4 MHz |
| Transducer type DS 4-4.5 treat depth | 4.5 mm |
| Transducer type DS 10-1.5N treat frequency | 10 MHz |
| Transducer type DS 10-1.5N treat depth | 1.5 mm |
| Transducer type DS 10-1.5N scan length | 14 mm |
| Electrical input | 100-240 VAC, 50-60 Hz |
| Ventilation clearance | at least 4 inches/ 10 cm |
| Control unit ingress protection | IPx0 |
| Mated transducer and handpiece ingress protection | IPx1 |
| Ready state timeout | 40 seconds |
Ratings & reviews
No product reviews have been published.
No store reviews have been published.
Supplier
Product description
The Ulthera System image/treat transducer features integrated treat guides that mark the maximum treatment line length and a center point at the front tip. These visual references help practitioners align each linear energy delivery consistently across the treatment area. The guides correspond to the transducer's active length, supporting precise placement of thermal coagulation points during therapy sessions. A label atop each transducer identifies type, expiration date, and other essential information for proper use and inventory management. This component works with the handpiece's SEE and TREAT pushbuttons to transition smoothly between imaging and therapy states. The transducer latches securely into the handpiece receptacle, with automatic detection by the control unit upon insertion. Multiple transducer options with varying frequencies and depths are available to address different tissue layers, all utilizing the same guided linear treatment approach for non-invasive dermatological aesthetic applications.
| Parameter | Specification |
|---|---|
| Model | Ulthera System |
| Image depth | up to 8 millimeters |
| Scan length | 25 mm |
| Transducer type DS 7-3.0 treat frequency | 7 MHz |
| Transducer type DS 7-3.0 treat depth | 3.0 mm |
| Transducer type DS 4-4.5 treat frequency | 4 MHz |
| Transducer type DS 4-4.5 treat depth | 4.5 mm |
| Transducer type DS 10-1.5N treat frequency | 10 MHz |
| Transducer type DS 10-1.5N treat depth | 1.5 mm |
| Transducer type DS 10-1.5N scan length | 14 mm |
| Electrical input | 100-240 VAC, 50-60 Hz |
| Ventilation clearance | at least 4 inches/ 10 cm |
| Control unit ingress protection | IPx0 |
| Mated transducer and handpiece ingress protection | IPx1 |
| Ready state timeout | 40 seconds |